Filter products
AQUATO
VORTEILE
- Großes Produktspektrum
- Umfassendes Sortiment
- Transparenter Bestellablauf
- Persönliche Beratung
- 24h Expressversand möglich
blue float switch for sewage pumping stations in ATEX operation
blue float switch for sewage pumping stations in ATEX operation
Microprocessor control with motor protection 4-6 Afor two direct-starting 3-phase sewage pumps with or without explosion protectionsuitable for MultiCut 20/2M Pluscompact ISO housing, protection class IP44, W×H×D (in mm): 250 × 275 × 150illuminated LCD display with plain text menu navigation and multifunction button, membrane keys for manual-0-automatic and reset, status LED displaydisplay information on operating mode, faults, water level and current power consumptionoperating counter, logbook, automatic test run, activatable maintenance indicatoralarm buzzer and 2 changeover volt-free contacts for alarm forwardingmains-independent high-water alarm (battery required)2 contactors 4 kW and adjustable motor protection switchesintegrated safety separation barrier for dry-running protection switch in terms of ATEX directive2-circuit dynamic pressure level switch with programmable follow-up timedynamic pressure bell set and dry-run protection float switch includedATEX-ready as standard:dry-running protection, max. pump runtime setting and mechanical motor current monitoring only at AQUATO included in scope of delivery: control is plug-ready: CEE phase-changing plug 16 A with 1 m cable attached 9 V rechargeable battery NMH for mains-independent high water alarm
Microprocessor control with motor protection 4-6 Afor two direct-starting 3-phase sewage pumps with or without explosion protectionsuitable for MultiCut 20/2M Pluscompact ISO housing, protection class IP44, W×H×D (in mm): 250 × 275 × 150illuminated LCD display with plain text menu navigation and multifunction button, membrane keys for manual-0-automatic and reset, status LED displaydisplay information on operating mode, faults, water level and current power consumptionoperating counter, logbook, automatic test run, activatable maintenance indicatoralarm buzzer and 2 changeover volt-free contacts for alarm forwardingmains-independent high-water alarm (battery required)2 contactors 4 kW and adjustable motor protection switchesintegrated safety separation barrier for dry-running protection switch in terms of ATEX directive2-circuit dynamic pressure level switch with programmable follow-up timedynamic pressure bell set and dry-run protection float switch includedATEX-ready as standard:dry-running protection, max. pump runtime setting and mechanical motor current monitoring only at AQUATO included in scope of delivery: control is plug-ready: CEE phase-changing plug 16 A with 1 m cable attached 9 V rechargeable battery NMH for mains-independent high water alarm
Microprocessor control with motor protection 6-10 Afor two direct-starting 3-phase sewage pumps with or without explosion protectionsuitable for MultiCut 35/2M and 36/2Mcompact ISO housing, protection class IP44, W×H×D (in mm): 250 × 275 × 150illuminated LCD display with plain text menu navigation and multifunction button, membrane keys for manual-0-automatic and reset, status LED displaydisplay information on operating mode, faults, water level and current power consumptionoperating counter, logbook, automatic test run, activatable maintenance indicatoralarm buzzer and 2 changeover volt-free contacts for alarm forwardingmains-independent high-water alarm (battery required)2 contactors 4 kW and adjustable motor protection switchesintegrated safety separation barrier for dry-running protection switch in terms of ATEX directive2-circuit dynamic pressure level switch with programmable follow-up timedynamic pressure bell set and dry-run protection float switch includedATEX-ready as standard:dry-running protection, max. pump runtime setting and mechanical motor current monitoring only at AQUATO included in scope of delivery: control is plug-ready: CEE phase-changing plug 32 A with 1 m cable attached 9 V rechargeable battery NMH for mains-independent high water alarm
Microprocessor control with motor protection 6-10 Afor two direct-starting 3-phase sewage pumps with or without explosion protectionsuitable for MultiCut 35/2M and 36/2Mcompact ISO housing, protection class IP44, W×H×D (in mm): 250 × 275 × 150illuminated LCD display with plain text menu navigation and multifunction button, membrane keys for manual-0-automatic and reset, status LED displaydisplay information on operating mode, faults, water level and current power consumptionoperating counter, logbook, automatic test run, activatable maintenance indicatoralarm buzzer and 2 changeover volt-free contacts for alarm forwardingmains-independent high-water alarm (battery required)2 contactors 4 kW and adjustable motor protection switchesintegrated safety separation barrier for dry-running protection switch in terms of ATEX directive2-circuit dynamic pressure level switch with programmable follow-up timedynamic pressure bell set and dry-run protection float switch includedATEX-ready as standard:dry-running protection, max. pump runtime setting and mechanical motor current monitoring only at AQUATO included in scope of delivery: control is plug-ready: CEE phase-changing plug 32 A with 1 m cable attached 9 V rechargeable battery NMH for mains-independent high water alarm
for level-dependent control of two single-phase pumps 50 Hzilluminated TFT touch displayautomatic operation with duty-standby mode and peak-loadmanual-0-automatic functionrotating field and phase monitoringincluding main switchcontactors 4 kWmotor protection switchestrigger range 0.63–1.0 A rated current ISO housing with transparent coverW×H×D(mm): 265 × 270 × 145protection class IP 66 (with closed housing cover)cable entry via cable glands level detection by digital and analog inputs:3 float switches, 1 high water float switchanalog input 4–20 mA for level probedynamic pressure measurement (pressure module required)3 freely programmable volt-free contacts230 V float switch connection for emergency function in case of control malfunction expandable with: pressure module, GSM-Module, battery module
for level-dependent control of two single-phase pumps 50 Hzilluminated TFT touch displayautomatic operation with duty-standby mode and peak-loadmanual-0-automatic functionrotating field and phase monitoringincluding main switchcontactors 4 kWmotor protection switchestrigger range 1.0–1.6 A rated current ISO housing with transparent coverW×H×D(mm): 265 × 270 × 145protection class IP 66 (with closed housing cover)cable entry via cable glands level detection by digital and analog inputs:3 float switches, 1 high water float switchanalog input 4–20 mA for level probedynamic pressure measurement (pressure module required)3 freely programmable volt-free contacts230 V float switch connection for emergency function in case of control malfunction expandable with: pressure module, GSM-Module, battery module
for level-dependent control of two single-phase pumps 50 Hzilluminated TFT touch displayautomatic operation with duty-standby mode and peak-loadmanual-0-automatic functionrotating field and phase monitoringincluding main switchcontactors 4 kWmotor protection switchestrigger range 1.6–2.5 A rated current ISO housing with transparent coverW×H×D(mm): 265 × 270 × 145protection class IP 66 (with closed housing cover)cable entry via cable glands level detection by digital and analog inputs:3 float switches, 1 high water float switchanalog input 4–20 mA for level probedynamic pressure measurement (pressure module required)3 freely programmable volt-free contacts230 V float switch connection for emergency function in case of control malfunction expandable with: pressure module, GSM-Module, battery module
for level-dependent control of two single-phase pumps 50 Hzilluminated TFT touch displayautomatic operation with duty-standby mode and peak-loadmanual-0-automatic functionrotating field and phase monitoringincluding main switchcontactors 4 kWmotor protection switchestrigger range 2.5–4.0 A rated current ISO housing with transparent coverW×H×D(mm): 265 × 270 × 145protection class IP 66 (with closed housing cover)cable entry via cable glands level detection by digital and analog inputs:3 float switches, 1 high water float switchanalog input 4–20 mA for level probedynamic pressure measurement (pressure module required)3 freely programmable volt-free contacts230 V float switch connection for emergency function in case of control malfunction expandable with: pressure module, GSM-Module, battery module
for level-dependent control of two single-phase pumps 50 Hzilluminated TFT touch displayautomatic operation with duty-standby mode and peak-loadmanual-0-automatic functionrotating field and phase monitoringincluding main switchcontactors 4 kWmotor protection switchestrigger range 4.0–6.3 A rated current ISO housing with transparent coverW×H×D(mm): 265 × 270 × 145protection class IP 66 (with closed housing cover)cable entry via cable glands level detection by digital and analog inputs:3 float switches, 1 high water float switchanalog input 4–20 mA for level probedynamic pressure measurement (pressure module required)3 freely programmable volt-free contacts230 V float switch connection for emergency function in case of control malfunction expandable with: pressure module, GSM-Module, battery module
for level-dependent control of two 3-phase pumps 50 Hzilluminated TFT touch displayautomatic operation with duty-standby mode and peak-loadmanual-0-automatic functionrotating field and phase monitoringincluding main switchcontactors 4 kWmotor protection switchestrigger range 1.0–1.6 A rated current ISO housing with transparent coverW×H×D(mm): 265 × 270 × 145protection class IP 66 (with closed housing cover)cable entry via cable glands level detection by digital and analog inputs:3 float switches, 1 high water float switchanalog input 4–20 mA for level probedynamic pressure measurement (pressure module required)3 freely programmable volt-free contacts230 V float switch connection for emergency function in case of control malfunction expandable with: pressure module, GSM-Module, battery module
AQUATO® TOPSELLER
AQUATO® menu structurefor AQUATO SBR, fixed bed and fluidized bed systems as well as trickling filter systems and plant beds4 cables with square plugs for the valves Possibility of pressure and current monitoringintegrated power failure notificationuse for 3 or 4 valve manifoldsoptional connection of a clear water pumpIOT capability / portal required
AQUATO® menu structureuniversal control for SBR, SSB®, fixed bed, moving bed, trickling filter systems and plant beds2 float switch inputs6 individually assignable outputseasy connection of existing valves and aggregatesinternal thermostat for control of a cabinet ventilation or heating systempower failure message as well as current & pressure monitoringdrain class C, N, D, D+P, D+H, D+P+Hconnection of an additional high water detectoralso suitable for plants of other manufacturers2nd compressor, additional compressor (only for aeration), charging pump, clear water pump, excess sludge pump, buffer pump/siphon,dosing pump for effluent class D+P, UV lamp for effluent class D+H, additional timed relays for all free outputs
submersible up to 12 m deepsuitable for pumping clean, chemically neutral waterfor use in cisterns and rainwater tanksintegrated pressure switch for automatically switching the pump on and offintegrated floating switch as dry-run protection
material: PE100, SDR11, PN10, butt-welded from mould fittings3x re-inforcded female thread 2"horizontal discharge connection suitable for installation of duplex pumping systemsfor rain- and greywater up to 17 m³/h flowperfect in combination with 2x pipework set DN 50
Housing is supplied without lock, key and without base plate for the compressor
including fastening setconnection pipe sideways G 1" malewithout connection cable
pre-assembled set consists of:1× ball valve 2"1× non-return valve 2"1× PP elbow 2"2× clamp coupling 2" × Ø 63 mm